Glass-fibre reinforced polyamide based (PA) technopolymer, black colour.
Support
Aluminium in natural colour.
Graduated contrast screen
White lacquered aluminium. It can be taken out before assembly to allow the insertion of level lines or words.
Float
Technopolymer, black colour, with a built-in magnetic element to activate the electric contact when the float reaches the contact threshold located at about 55 mm above the axis of the lower screw (data referred to mineral oil type CB68, according to ISO 3498, temperature 23°C).
Spacer sleeves
In polyamide based (PA) technopolymer. Essential in cases where the reservoir is made out of ferromagnetic material in order to prevent the interaction between the magnet and the metal mass of the reservoir.
Bracket with male connector
Perfectly watertight, incorporating the relay (reed) with two output conductors (NO and NC version) and/or with MAX temperature sensor (80°C) and/or temperature probe.
DIN 43650 C connector in glass-fibre reinforced polyamide based (PA) technopolymer, black colour.
4-pole M12x1 connector, with threading in glass-fibre reinforced polyamide based (PA) technopolymer certified self-extinguishing UL-94-V0, black colour, matte finish.
For a correct assembly see Warnings.
Female connector (DIN 43650 C)
With built-in cable gland and contact holder. Front or axial output (high or low) ensuring protection against water sprays (protection class IP 65 according to table EN 60529).
Standard executions
See configuration table.
Features and performances
The HCK-E-S level indicator with lateral connector output allows the level of intervention of the sensor to be minimised.
In case of use of an extension with angled connector, the direction of the cable output is shown in Fig.1.
Technical data
In laboratory tests carried out for a relatively limited time with the following liquids at a temperature of 23° C: mineral oil type CB68 (according to ISO 3498) for HCK, mineral oil type CB68 (according to ISO 3498) water or water/glycol-based solutions ( 50%) for HCK-GL, the resistance values were much higher than 35 bar.
For use with other fluids and under different pressure and temperature conditions, please contact ELESA Technical Department.
In any case we suggest to verify the suitability of the product under the actual working conditions.
Functioning of the MIN level electrical sensor
NO: the electrical contact closes on reaching the minimum level.
NC: the electrical contact is opened when it reaches the minimum level.
HCK-E-ST - HCK-E-ST-KN
Electrical features
MIN level sensor
Power supply
AC/DC
Electric contacts
NO normally open
NC normally closed
Maximum applicable voltage
NO: 140 Vac, 200 Vdc
NC: 140Vac, 150 Vdc
Maximum switching current
1 A
Maximum current
NO: 1.2A
NC: 2A
Maximum commutable power
NO: 10 Va
NC: 20 Va
Cable gland (only HCK-E-ST)
Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-ST)
Max. 1.5 mm2
Connector (only HCK-E-ST-KN)
M12x1
Do not mount this indicator in proximity to magnetic fields.
HCK-E-STL - HCK-E-STL-KN
Electrical features
MIN level sensor
Power supply
AC/DC
Electric contacts
NO normally open
NC normally closed
Maximum applicable voltage
NO: 140 Vac, 200 Vdc
NC: 140Vac, 150 Vdc
Maximum switching current
1 A
Maximum current
NO: 1.2A
NC: 2A
Maximum commutable power
NO: 10 Va
NC: 20 Va
Cable gland (only HCK-E-STL)
Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-STL)
Max. 1.5 mm2
Connector (only HCK-E-STL-KN)
M12x1
Do not mount this indicator in proximity to magnetic fields.
Functioning of the MAX temperature sensor
NO: the electrical contact closes when the pre-set temperature is reached at 80°C.
NC: the electrical contact opens when the pre-set temperature at 80°C is reached.
HCK-E-ST - HCK-E-ST-KN
Electrical features
MAX temperature sensor
Power supply
AC/DC
Electric contacts
NO normally open
NC normally closed
Voltage /
Maximum current
250 Vac - 2 A
(resistive loads)
115 Vac- 3A
24 Vdc - 3 A
12 Vdc - 4 A
Minimum current
500 mA
Cable gland (only HCK-E-ST)
Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-ST)
Max. 1.5 mm2
Connector (only HCK-E-ST-KN)
M12x1
Do not mount this indicator in proximity to magnetic fields.
Functioning of the temperature electrical probe (STL)
The working principle of the temperature probe is to measure the variation of resistance of a platinum element: 100 ohm = 0°C, 138.4 ohm = 100°C.
The function between temperature (T) and resistance (R) is approximately linear over a small temperature range: for example, if you assume that it is linear over the 0° to 100°C range, the error at 50°C is 0.4°C.
For precision measurement, it is necessary to linearise the resistance to give an accurate temperature. The most recent definition of the function between resistance and temperature is International Temperature Standard 90 (ITS-90). The function between resistance and temperature, obtained in laboratory tests, measuring directly the resistance value on the contacts is shown in the graph. We suggest, anyway, to set the system in order to compensate both heat dissipation and cable resistance.
The temperature variation of 1°C causes a 0.384 ohm variation in the probe resistance. Therefore, even a small error in the resistance measurement (for example, if the resistance of the cables connecting to the probe were not considered) translates into a significant error in the temperature measurement.
Because of the low signal levels, it is important to keep any cables away from electric cables, motors, switchgear and other devices that may emit magnetic or electrical noise. Using screened cable, with the screen grounded at one end, may help to reduce interference.
Furthermore, if long connection cables are used, make sure that the signal measurement and reception device is designed to compensate for the resistance of the cables themselves.
HCK-E-STL - HCK-E-STL-KN
Electrical features
Temperature probe
Power supply
AC/DC
Maximum current
1mA
Cable gland (only HCK-E-STL)
Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-STL)
Max. 1.5 mm2
Connector (only HCK-E-STL-KN)
M12x1
Do not mount this indicator in proximity to magnetic fields.
Special executions on request
Column level window in transparent methylmatacrylate (PMMA) for max 70°C use.
Polyamide based technopolymer float (from HCK.127) red colour.
NBR float (from HCK.176) black colour with AISI 316 stainless steel spiral for special executions, viscous liquids, high temperatures.
Indicators with level visibility (quota) up to 1429 mm and fixing holes with centre distance (quota f) up to 1500 mm.
Packing rings in special material depending on the customer's needs.
Special screw with nickel-plated brass tap to be fitted to the lower assembly end for any maintenance operation requiring the indicator exclusion.
Accessories on request
FC-M12x1: extensions with 4 pole M12 female axial connector.
Female connector assembly instructions
Remove the connector from the indicator by unscrewing the set screw placed on the connector, take the contact holders out and loosen the cable gland.
a) HCK-E-ST: insert the cable into the connector (standard connector) and connect the wires to terminals 1 and 2 for the operation of the MIN level sensor, to terminals 3 and ground (4) for the operation of the MAX temperature sensor.
b) HCK-E-STL: insert the cable into the connector (standard connector) and connect the wires to terminals 1 and 2 for the operation of the MIN level sensor, to terminals 3 and ground (4) for the operation of the temperature probe.
Assemble by pressing the contact holder into the connector in the required position.
Screw the connectors to the indicator and then tighten the cable glands.
LOOKING FOR SOMETHING:
Feeling overwhelmed with what product to choose?
Don’t delay, give OIC a call and talk to us about your industrial application. Our aim is to help your business choose the right Elesa+Ganter element for the function you need. Whether you need to clamp, close, connect, control, level, manoeuvre, measure or set. OIC has an Elesa+Ganter machine element to fit your need.
We want to find out about your industrial application need and where we can help. Our contact details are below.
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.OkCookie policy